Commentary · 1 Dec 2025
ArticlePublished 2019
Safety and Effectiveness of FlexyRapandreg; Cobalt-Chromium Rapamycin-Eluting Stents with Biodegradable Polymer in Coronary Artery Disease: Results from a 2-year, Multicenter Postmarketing Study in India
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Background: Data supporting effectiveness and safety of indigenously developed drug-eluting stents (DES) for treatment of Indian patients with de novo coronary artery disease (CAD) remain scarce. In this postmarketing surveillance (PMS) study, we evaluated effectiveness and safety of an indigenously developed DES, FlexyRap®, for treatment of Indian patients with obstructive native artery. Methods: We enrolled 100 patients with obstructive native artery who underwent Percutaneous Coronary Intervention (PCI) using DES technology called FlexyRap®. The primary efficacy endpoint was Target Vessel Revascularization (TVR) at 1-year follow-up. The primary safety outcome was incidence of a Major Adverse Cardiac Event (MACE), defined as a composite of cardiac death, myocardial infarction, target lesion revascularization, and TVR at 12 months. Secondary efficacy endpoints included procedural and device success. Additional safety endpoints were incidences of any device-related Serious Adverse Events (SAEs) and stent thrombosis. Results: In this study, of the 100 patients treated with FlexyRap®, data was available for 96 patients at the end of the 24-month surveillance period. Device and procedural success was observed in 100% of patients. At 12 months after implantation of FlexyRap®, 6.25% of patients developed MACE; the incidence of MACE remained at 6.25% at completion of the 24-month PMS period. The primary endpoint of TLR developed in 5% of patients. The MACE-free survival rate was 93.78%. No SAE leading to death was reported throughout the 24-month surveillance period. No patient experienced AEs that led to major bleeding, permanent disability, or death. Conclusion: FlexyRap® was safe and effective in Indian patients with CAD. Results of the study are encouraging and support clinical benefits of the indigenously developed FlexyRap® DES for treating Indian patients with CAD in a real-world scenario.
Keywords
Subjects
CardiologyAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
More from this journal
The newest in Journal of Interventional and General Cardiology.
Commentary · 1 Dec 2025
Biomechanics of Transcatheter Mitral Valve Leaflet Coaptation
Brief report · 1 Dec 2025
Percutaneous Myocardial Partitioning: Impact on Septal Mechanics
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Interventional and General Cardiology
- SubjectCardiology
- BylineArticles whose byline prints “Sameer Dani”
- BylineArticles whose byline prints “Mamtesh Gupta”
- BylineArticles whose byline prints “Rashmit Pandya”
- BylineArticles whose byline prints “Krishna Goyal”
- BylineArticles whose byline prints “Preeti Vani”
- BylineArticles whose byline prints “Malte Neuss”
- BylineArticles whose byline prints “Prashant Janbandhu”
