The concept design of air nebulizer cup for medical inhalers

Authors: Marek Ochowiak, Magdalena Matuszak, Sylwia Włodarczak, Anna Gościniak

Poznan University of Technology, Poland; Phytopharm Kleka, Poland

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

The aim of this work was to analyze the effect of aeration on distribution of drop sizes in the aerosol. The aerosol was generated with a pneumatic medical nebulizer fitted with a modified nebulizer cup connected to the additional source of aerating gas. The size of drops formed was analyzed with a digital microphotography with prior capture of drops onto the immersive liquid layer. The photos obtained were analyzed in Image-Pro Plus. The mean drop diameter and volumetric share of drops of 5 Ã?µm and 10 Ã?µm were analyzed. Based on results, the effect of aeration of liquid on the dispersion process was evaluated. Modification of the nebulizer cup consists in making four holes in the bottom of this vessel. All tubes (used as the aerator) coming out from the holes were connected to the collector to which an additional air stream from another Medel Family pneumatic nebulizer was provided via a hose by rotameter and valve. The valve enables control of the flow rate of additional air fed to the nebulization cup. Dispersion Atomization in pneumatic medical nebulizer with different gas flow rates by dispersed liquid was tested. The tests were conducted within the flow rate of additional gas from 1.39x10-5 to 8.33x10-5 m3/s. The work also analyzed the size of bubbles flowing out from a single aerator orifice with a flow rate of additional gas from 6.44x10-6 to 8.33x10-5 m3/s. The analysis of drops size histograms shows that with the higher flow rate of gas, the number of large drops decreases and there are more small drops. With the higher gas flow rate, the drops size distribution curve clearly moves towards the smaller drops. Based on the experimental studies it was found that: An increase in the flow rates of additional gas leads to the increase in the number of small droplets, an increase in the flow rate of aeration gas decreases the number of drops of large diameter, the mean droplet diameter decreases with the increase of the flow rate of additional gas, the results allow to propose a correlation in form of, which describes the mean diameter of droplet (SMD), depending on the volumetric flow rate of additional gas (expressed by Reynolds number Reg), the bubble volume discharging through a single orifice increases with increasing the flow rate of aeration gas and the modifications of construction of atomizer may help to improve the effectiveness of the aerosol therapy by the decrease in the droplets diameter.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Journal of Developing Drugs.

All its articles

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Developing Drugs
  • SubjectPharmaceutical Sciences
  • BylineArticles whose byline prints “Marek Ochowiak”
  • BylineArticles whose byline prints “Magdalena Matuszak”
  • BylineArticles whose byline prints “Sylwia Włodarczak”
  • BylineArticles whose byline prints “Anna Gościniak”