Scholars Central

Conference abstractPublished 17 Jun 2013

Use of glycosylated horseradish peroxidase to improve the stability of an amperometricenzymebased biosensor

Authors: Griselle Hernandez-Cancel, Damaris Suazo, Johnsue Medina-Guzman, Maria Rosado-González, Christian Torres-López, Carlos Cabrera, Liz Díaz, KaiGriebenow

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

One of the drawbacks of enzyme-based sensors is the rapid loss of activity because enzymes are very sensitive to their environment and thermodynamically intrinsically unstable. Several studies have shown that covalent modification of enzymes with glycans (Gly) can prevent activity loss and improve their long-term stability. To address this problem we glycosylate horseradish peroxidase (HRP) with lactose to construct a simple and low cost amperometric horseradish peroxidase biosensor based on a 4-mercaptobenzoic acid self-assembled monolayer on gold nano-particles (AuNPs) at the surface of a glassy carbon (GC) electrode. We compared the sensitivity, linear range, and detection limit (LOD) of the biosensor using the native and glycosylated form of the enzyme for this biosensor design. Circular dichroism (CD) spectra showed no change as result of glycosylation with lactose. The highest sensitivity of the biosensor to hydroquinone was obtained for the Lac-HRP-4-MBAAuNPs- GC biosensor with 370 nAμM-1cm-2 compared to 308 nAμM-1cm-2 for the HRP-4-MBA-AuNPs-GC biosensor; showing that the glycosylated form of the enzyme catalyzed the reduction of hydroquinone more rapidly and efficiently than the native form of the enzyme. The LOD observed for the native HRP biosensor was 0.74 and 0.83 for the Lac-HRP biosensor respectively. The linear range for both biosensors was from 5- 300 μM. The Ea value obtained for native HRP biosensor was 3.49 kJmol-1 and 1.20 kJmol-1 for Lac-HRP biosensor. From this study we found that glycosylation of HRP does not affect the catalytic property of the enzyme. Also, the glycosylated HRP showed an improvement on the biosensor sensitivity for detection of hydroquinone.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Biosensors & Bioelectronics.

All its articles

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalBiosensors & Bioelectronics
  • BylineArticles whose byline prints “Griselle Hernandez-Cancel”
  • BylineArticles whose byline prints “Damaris Suazo”
  • BylineArticles whose byline prints “Johnsue Medina-Guzman”
  • BylineArticles whose byline prints “Maria Rosado-González”
  • BylineArticles whose byline prints “Christian Torres-López”
  • BylineArticles whose byline prints “Carlos Cabrera”
  • BylineArticles whose byline prints “Liz Díaz”
  • BylineArticles whose byline prints “KaiGriebenow”