Article · 29 Dec 2025
Conference abstractPublished 14 May 2012
Bedside reduced lead electroencephalography can be used to make the diagnosis of nonconvulsive status epilepticus in the Emergency department
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Objectives: Electroencephalography (EEG) is indicated for diagnosing nonconvulsive status epilepticus in a patient who has altered level of consciousness (ALOC) after a motor seizure. A study in a neonatal population found 94% sensitivity and 78% specificity for detection of seizure using a single-lead device. This study aims to show that a reduced montage EEG would detect 90% of seizures detected on standard EEG. Methods: A portable Brainmaster EEG device was available in the ED at all times. The indication for enrollment into the study was ALOC with a known history of seizures. The ED physician obtained informed consent from the legally authorized representative (LAR), while an ED technician attached the electrodes to the patient, and a research associate attached the electrodes to the wiring routing to the portable EEG module. A Board-Certified Epileptologist interpreted the tracings via the Internet. Simultaneously, the ED physician ordered a standard 23-lead EEG, which would be interpreted by the neurologist oncall to read EEGs. The epileptoglogist�s interpretation of the reduced montage EEG was compared to the results of the 23-lead EEG, which was considered the gold standard for detecting seizures. Results: 12 of 12 patients or 100% had the same findings on reduced montage EEG as standard EEG. 1 of 12 patients or 8% had nonculsive seizure activity. Conclusion: The results are consistent with prior studies which have shown that 8-25% of patient who have had a motor seizure continue to have nonconvulsive seizure activity on EEG. This study shows that a bedside reduced-montage EEG can be used to make the diagnosis of nonconvulsive status epilepticus (NCSE) in the emergency department. Further study will be conducted to see if this technology can be applied to the inpatient neurololgical intensive care unit setting.
Subjects
Neuroscience & NeurologyAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
More from this journal
The newest in Biosensors & Bioelectronics.
Brief report · 29 Dec 2025
Advancing Biosensors for Personalized Health Monitoring
Brief report · 29 Dec 2025
Hybrid Biosensors: Enhanced Detection for Health
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalBiosensors & Bioelectronics
- SubjectNeuroscience & Neurology
- BylineArticles whose byline prints “J. Brenner”
- BylineArticles whose byline prints “P. Kent”
- BylineArticles whose byline prints “S. Wojcik”
- BylineArticles whose byline prints “W. Grant”