Scholars Central

Research articlePublished 2016

A Comparison of Three Techniques for Measurement of Intraocular Pressure in Normal Eyes

Authors: Haya M. Al Farhan

Journal of Clinical and Experimental Ophthalmology

Volume 7 · Issue 3 · Pages 1–6

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Objectives: To compare the precision of intraocular pressure (IOP) measurements acquired using an ocular response analyser (ORA), Auto Kerato-Refracto-Tonometer (TRK-1P), and Goldmann applanation tonometer (GAT) in healthy eyes. Methods: In this prospective study, one eye of each of 57 normal subjects was randomly selected for analysis. Measurements of the IOP were performed using ORA, TRK-1P, and GAT, and measurements of corneal hysteresis (CH), corneal resistance factor (CRF), and central corneal thickness (CCT) were performed using ORA. Repeatability was assessed by the coefficient of variation (CV) and interclass correlation coefficients (ICCs). Agreement among tonometers was assessed by Bland–Altman plots and one-way ANOVA. Results: The average IOPs measured using Goldmann-correlated IOP (IOPg), corneal-compensated IOP (IOPcc), TRK-1P, and GAT (± SDs) were 15.13 ± 2.76, 14.39 ± 2.59, 16.54 ± 2.93, and 15.21 ± 2.54 mmHg, respectively. Intra-observer agreement across all tonometers was strong and slightly higher for GAT and IOPg than for TRK-1P. The intra-observer CVs for GAT IOPg, and TRK-1P, were 4.22 (ICC=0.94), 4.99 (ICC=0.93), and 6.69 (ICC=0.86), respectively. Inter-observer agreement between various measurement methods was evaluated with Bland-Altman plots with multiple measurements per subject and ICCs. Results indicated fairly poor agreement across measurement methods, as supported by large limits of agreement and ICCs. Conclusion: GAT, ORA, and TRK-1P are highly reliable methods for measurement of the IOP; however, the instruments cannot be used interchangeably.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Journal of Clinical and Experimental Ophthalmology.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Clinical and Experimental Ophthalmology
  • SubjectOphthalmology & Optometry
  • BylineArticles whose byline prints “Haya M. Al Farhan”