Scholars Central

Research articlePublished 2013

Sagittal Lumbar Alignment Following Axial Lumbar Interbody Fusion with TranS1

Authors: Nitin Kukkar, CPT Matthew C Mai, Ashim Gupta, Devraj Banerjee, Neru Bedi, Benjamin J Main, Per Freitag

Journal of Spine

Volume 2 · Issue 5 · Pages 1–6

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Design: Retrospective study. Objective: To examine and compare pre/postoperative sagittal alignment of the lumbar spine following AxiaLIF® and to identify patient category with respect to preservation/restoration of lumbar lordosis. Background: Interbody arthrodesisis an effective treatment for lower back pain and provides immediate structural support with high fusion rates. AxiaLIF® is an interbody device to be implanted through a paracoccygeal approach. Sagittal alignment change after AxiaLIF® has not been studied in past literature. Methods: Retrospective study of all patients who underwent a 360° lumbar interbody fusion at L5-S1 and L4-S1 with AxiaLIF® between Nov. 2008 and Sept. 2009. Surgeries were performed with patients prone on a Jackson table. Lumbar Cobb angles were measured at L1-S1, L4-S1 and individual lumbar levels. The sacral slope and percentage of total lordosis coming from the L4-S1 levels were also recorded. Results: 60 patients identified for inclusion (mean age: 44 years). No difference in total average lordosis was observed preoperatively (47.9º) versus postoperatively (47.7º). The difference between pre and postoperative Cobb angles at the L4-S1 and L4-L5 levels was statistically significant (p=0.022 and 0.029, respectively). The change in percentage of total lordosis coming from L4-S1 segments (68.9% preoperatively vs. 56.5% postoperatively) was also significantly different (p=0.0004). A >10º postoperative change in total lordosis, L4-S1, and SS occurred in 18%, 20%, and 11% respectively. 50% and 43% of patients had a >5º change at the individual segments of L4-L5 and L5-S1. Conclusions: A significant portion single and multilevel fusions with AxiaLIF® had a statistically significant change at the L4-5 and L4-S1 levels. The percentage of total lordosis from the L4-S1 level decreased significantly in the multilevel group. Further observation will determine if change in alignment will impact outcomes or accelerate adjacent level disease.

Subjects

Orthopaedics

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Spine
  • SubjectOrthopaedics
  • BylineArticles whose byline prints “Nitin Kukkar”
  • BylineArticles whose byline prints “CPT Matthew C Mai”
  • BylineArticles whose byline prints “Ashim Gupta”
  • BylineArticles whose byline prints “Devraj Banerjee”
  • BylineArticles whose byline prints “Neru Bedi”
  • BylineArticles whose byline prints “Benjamin J Main”
  • BylineArticles whose byline prints “Per Freitag”