Comparison of MatriXX evolution and MatriXX resolution dosimetry systems and their sensitivity to gantry angle variations in gamma index measurements
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
This study investigates the dosimetric performance of two advanced dosimetry systems, MatriXX evolution and MatriXX resolution, using gamma index measurements under fixed and varying gantry angles. The study aims to elucidate the impact of system characteristics and gantry angulation on dosimetric accuracy in radiation therapy quality assurance. Accurate dose delivery in radiation therapy relies on robust quality assurance measures provided by dosimetry systems. MatriXX evolution and MatriXX resolution are widely recognized for their ability to capture dose distributions, with MatriXX resolution offering higher detector density and spatial resolution compared to MatriXX evolution. The gamma index, a metric commonly used for dosimetric evaluation, quantifies the agreement between calculated and measured dose distributions, crucial for ensuring treatment efficacy and patient safety. Measurements were performed using the Elekta Infinity LINAC operating at 6 MV and 6 FFF (Flattening Filter Free) modes. Dose distributions were calculated using the Monaco Monte Carlo treatment planning system, simulating clinical scenarios with both fixed gantry angle (0°) and varying gantry angles. Gamma index evaluations were conducted using criteria of 2%/2 mm and 3%/3 mm to assess dosimetric accuracy. Analysis of gamma index results revealed significant differences between MatriXX evolution and MatriXX resolution. MatriXX resolution consistently demonstrated superior gamma index values, particularly under strict criteria (2%/2 mm), attributable to its enhanced detector density and spatial resolution capabilities. Variations in gantry angle introduced notable changes in gamma index values for both dosimetry systems, highlighting the influence of beam orientation on dosimetric accuracy. In conclusion, this study underscores the critical role of dosimetry system characteristics and gantry angulation in radiation therapy quality assurance. MatriXX resolution's superior performance over matriXX evolution in detecting small dose discrepancies underscores its suitability for precise dosimetric evaluations. The findings emphasize the necessity of comprehensive QA protocols considering angular effects to ensure accurate radiation dose delivery in clinical practice.
Subjects
Oncology & CancerAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
More from this journal
The newest in Onkologia i Radioterapia.
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalOnkologia i Radioterapia
- SubjectOncology & Cancer
- BylineArticles whose byline prints “El Ghalmi Mohammed”
- BylineArticles whose byline prints “El Mahjoub Chakir”
- BylineArticles whose byline prints “Lakbir El Hamidi”
- BylineArticles whose byline prints “Raoui Yasser”
- BylineArticles whose byline prints “Herrassi Yassine”
- BylineArticles whose byline prints “Oustous Aziz”
- BylineArticles whose byline prints “Jioudy Basma”
- BylineArticles whose byline prints “Errouadi Morad”