ArticlePublished 1 Nov 2023
The evaluation of the novel efficiency index in relative to the conformity indices in stereotactic radiosurgery for patients with arteriovenous malformation
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Background: Stereotactic radiosurgery (SRS) is distinguished by high levels of conformity and high radiation gradients from the target's periphery to surrounding normal tissues. treatment regimens for radiosurgery should be adjusted by reducing the amount of dosage delivered to the surrounding tissue while increasing the amount of radiation delivered to the target volume. There have been many different indexes suggested to assess the quality of a radio surgical plan, but they all have some drawbacks. To overcome the limitations of the currently used metrics, a novel metric is proposed by Ian Paddick and his team called the efficiency index (ƞ50%). Method: Calculate the efficiency index (50%), which is based on the idea of integral dosage calculation: ƞ50% = integral dose TV/ integral dosePIV50% the integral dosage (volume times mean dose). The TV and PIV50% differential Dose Volume Histograms (DVHs) are an alternative. The amount of energy inside the PIV50% that falls into the target is effectively represented by the resultant 50% value. The potential range of this value is between 0 and 1, with 1 denoting perfection. The index yields a single number that incorporates conformance, gradient, and mean dosage to the target. 50 clinical SRS designs were used to get the value of 50%. Results: The evaluation of ƞ50% for the 50 plan treatments used in SRS ranged between the lower percentage of 43% and the upper percentage of 84%, with a mean value recorded of 64% in this study. The result was shown a strong relationship between the efficiency index and essential parameters in treatment plan evaluation of the arteriovenous malformations. Conclusion: The efficiency index that had been introduced is considered an innovative method for assessing the quality of the plan since it has the ability to combine the conformity, gradient, and mean dosage into a single indicator. It provides a numerical value for the proportion of the dosage presented by "does good" to the amount that "does harm."
Subjects
Oncology & CancerAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalOnkologia i Radioterapia
- SubjectOncology & Cancer
- BylineArticles whose byline prints “Arkan M Mhal”
- BylineArticles whose byline prints “Mohsen Hamoud Jasim”
- BylineArticles whose byline prints “Abbood Abbas Abbood”