Background: Several complications may be correlated with difficult airway up to death. Fiberoptic bronchoscope is the gold stander to deal with difficult intubation. Airtraq laryngoscope and C-MAC® video laryngoscope are new devices that are used successfully for tracheal intubation. We compared using C-MAC D-blade video laryngoscope, Airtraq laryngoscope, and Fiberoptic bronchoscope for intubation of patient likely to have difficult intubation. Patients and methods: Ethical committee permission was obtained before 120 adult patients (ASA I-III) with expected difficult intubation were incorporated in this prospective study. Participants were randomly distributed to 3 equal groups to be intubated using either C-MAC D-blade (group 1), Airtraq (group 2), or Fiberoptic technique (group 3) after anesthesia was induced. Our primary outcome was time to tracheal intubation. Intubation data, hemodynamics, and SpO2 were evaluated. Results: Time to visualize the vocal cords (T1) and time to tracheal intubation (T2) were significantly shorter in CMAC D-blade group (group 1) and Airtraq group (group 2) than Fiberoptic group (group 3) and there was insignificant variance between group 1 and group 2. All participants were intubated in the 1st attempt except one in C-MAC Dblade group who needed 2 intubation attempts. There were insignificant variances between the 3 groups regarding number of successful trial (success rate), and manipulation used to improve vocal cord visualization or intubation. Sore throat grades were significantly lower in group 2 and 3 than group 1. Lowest SpO2 was significantly lower in group 3 than the other 2 groups. Mean arterial blood pressure and heart rate measured at 1 min and 3 min after intubation were significantly higher in group 1 than group 2 and 3. Conclusion: When compared to Fiberoptic bronchoscope both C-mac D-blade and Airtraq comparably showed shorter time to visualize vocal cords and intubate patients with anticipated difficult intubation.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Anesthesia & Clinical Research.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalAnesthesia & Clinical Research
  • SubjectAnaesthesia & Pain
  • BylineArticles whose byline prints “Hesham M Marouf”
  • BylineArticles whose byline prints “Naglaa Khalil”