Research articlePublished 30 Jun 2015
DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE ESTIMATION OF SERATRODAST IN BULK AND TABLET DOSAGE FORM
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
A simple, precise, rapid and accurate reverse phase HPLC method was developed for the estimation of Seratrdast in tablet dosage form.ZobraxEclipseXDB-C18, 150x4.6 mm 5 μm partical size, with mobile phase consisting of water: acetonitrile in the ratio of 30:70 v/v was used. The flow rate was 1.0 ml/min and the effluents were monitored at 265 nm. The retention time& Recovery time was 8.07min&3.273. The detector response was linear in the concentration of 15-180 mcg/ml. The respective linear regression equation being Y= 32147.7x+58628. The limit of detection and limit of quantification was 0.015mcg and 0.03mcg/ml respectively. The percentage assay of Seratrodast was 99.43 %. The method was validated by determining its accuracy, precision and system suitability.
Subjects
Pharmaceutical SciencesAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalInternational Journal of Pharmacy
- SubjectPharmaceutical Sciences
- BylineArticles whose byline prints “J. Raghuram”