Research articlePublished 7 Sep 2012
DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE ESTIMATION OF BENFOTIAMINE IN BULKAND DOSAGE FORM
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
A new simple, precise, sensitive and validated RP-HPLC method wasdeveloped for the estimation of Benfotiamine in bulk and pharmaceutical dosage form. The chromatographic conditions used for the separation was Phenomenex Luna C18 (4.6x250mm,5μ) and mobile phase comprised of acetonitrile : methanol : water: 0.1% OPA (40:20:35:5 v/v). The flow rate was 1.0 ml/min with detection at 249 nm. The retention time was found to be 3.84 min.The linearity was found to be in the range of 5-35 μg/ml for benfotiamine with correlation coefficient of 0.9999. The proposed method is accurate with 99.278% -100.791 % recovery and precise (%RSD of repeatability, intra-day and inter-day variations were 0.53, 0.45-0.67, 0.58-0.79).The limit of detection (LOD) and limit of quantitation (LOQ) were found to be 0.1448 and 0.4388 μg/ml respectively.The method was successfully applied to pharmaceutical formulation because no chromatographic interferences from tablet excipients were found.
Subjects
Pharmaceutical SciencesChemistryAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalInternational Journal of Pharmaceutical, Chemical and Biological Sciences
- SubjectPharmaceutical Sciences
- SubjectChemistry
- BylineArticles whose byline prints “B.Pavan Adithya”
- BylineArticles whose byline prints “M.Vijayalakshmi”