Scholars Central

Research articlePublished 6 Jul 2020

Comparative Study of Stress Response to Intubation between King Vision and Macintosh Laryngoscope in Routine Airway Management

Authors: Ningthoujam Anita Devi, Takhelmayum Hemjit Singh, Deitho Koza, Nongosal Kirha, Raghupathi Ramasamy, Shammy Nazarudeen

Journal of Evidence-Based Medicine and Healthcare

Volume 7 · Issue 27 · Pages 1–4

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

BACKGROUND Laryngoscopy and intubation are known to cause exaggerated haemodynamic response and may have deleterious respiratory, neurological and cardiovascular effects. Among the various interventions employed to obtund these responses, the role of King Vision Video Laryngoscope (KVVL) was reported in some studies. So, we would like to compare the haemodynamic responses between the conventional Macintosh laryngoscope and KVVL. METHODS The study was a prospective, randomized one in which 90 adult patients of either sex, aged 18-60 years undergoing elective surgery under general anaesthesia with endotracheal intubation were enrolled in either group of 45 patients each to be subjected to KVVL (Group K) or Macintosh laryngoscope (Group M) for orotracheal intubation. Haemodynamic parameters such as heart rate and blood pressure were recorded every minute for the first 5 minutes after intubation and thereafter every two minutes till the 15th minutes. The time taken for laryngoscopy and intubation were also recorded and P<0.05 was deemed to be significant. RESULTS Demographic parameters such as age, sex, ASA and body mass index were comparable in the two groups (P<0.05). Intubation time was significantly longer in group K (20.74 ± 8.81 sec) as compared to group M (13.23 ± 7.60 sec). The heart rate and mean arterial blood pressure increased from the baseline value to a maximum at around 7th minute post intubation and thereafter receded to approach its baseline value in 15th minute and the difference became significant from the 5th minute onwards till the 15th minute. CONCLUSIONS King Vision Video Laryngoscopy was found to be more effective in reducing haemodynamic responses to laryngoscopy as compared to conventional Macintosh laryngoscopy.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Journal of Evidence-Based Medicine and Healthcare.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Evidence-Based Medicine and Healthcare
  • SubjectNursing & Healthcare
  • BylineArticles whose byline prints “Ningthoujam Anita Devi”
  • BylineArticles whose byline prints “Takhelmayum Hemjit Singh”
  • BylineArticles whose byline prints “Deitho Koza”
  • BylineArticles whose byline prints “Nongosal Kirha”
  • BylineArticles whose byline prints “Raghupathi Ramasamy”
  • BylineArticles whose byline prints “Shammy Nazarudeen”