Scholars Central

Research articlePublished 2015

Establishing measurement of uncertainty for simultaneous bio-analytical method by LC-MS/MS

Authors: James D. Terish Bino, Kannappan, Sasi Jith, Suresh Kumar

Der Pharmacia Sinica

Volume 6 · Issue 2 · Pages 45–51

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

The objective of this activity is to evaluate the expanded uncertainty in the simultaneous bio-analysis of L-Carnitine, an endogenous compound and Metformin a biguanide which is used as treatment for T2DM. This simultaneous method is developed and validated using LCMSMS in human plasma[1]. This method is developed to establish a single method which can be used as the prognostic tool, TDM and for bio-analysis drug Metformin of T2DM. To use this method for bio-analysis and TDM it is validated as per ICH guidelines and found to be within the acceptance criteria. Using the precision data the combined uncertainty was calculated as per the GUM guidelines and the MOU for the method was established. Method was developed using the UFLCMS (Ultra Flow liquid chromatography mass spectrometer) for the simultaneous estimation of Metformin and L-Carnitine in human plasma with LOQ and ULOQ of 43.483ng/ml and 639.450 ng/ml for Metformin and 2.289µg/mL and 33.675 µg/mL for L-Carnitine respectively. Linearity was established by considering Concentration maximum for Metformin and normal value of L-Carnitine[1]. The precision data was used for evaluating the MOU as per GUM guidelines[2]. MOU was found to be ±1.89 for L-Carnitine and ± 0.9 7 for Metformin. MOU is needed to be considered for analysis and the validated data need is evaluated by applying the correction. As the MOU is established this method can be used as a prognostic tool and by calculating the systematic and random error the possible method error is evaluated.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Der Pharmacia Sinica.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalDer Pharmacia Sinica
  • SubjectPharmaceutical Sciences
  • BylineArticles whose byline prints “James D. Terish Bino”
  • BylineArticles whose byline prints “Kannappan”
  • BylineArticles whose byline prints “Sasi Jith”
  • BylineArticles whose byline prints “Suresh Kumar”