COMPARISON OF INTRAOCULAR PRESSURE MEASUREMENT WITH NON-CONTACT TONOMETRY AND APPLANATION TONOMETRY AMONG VARIOUS CENTRAL CORNEAL THICKNESS GROUPS
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
BACKGROUND Glaucoma is the second leading cause of blindness worldwide. Intraocular Pressure (IOP) is the only known modifiable risk factor that has been shown to delay progression in both ocular hypertension and glaucoma patients. Clinical measurement of IOP has undergone several technical advances from the initial digital tension measurements, through indentation tonometry, to applanation tonometry and non-contact tonometry. This study was done to compare the intraocular pressure (IOP) measurements with Non Contact Tonometry (NCT) and Goldmann Applanation tonometry (GAT) and to compare NCT IOP and GAT IOP among various central corneal thickness (CCT) groups. MATERIALS AND METHODS IOP measurements were done by NCT and then by GAT followed by CCT. All IOP readings were taken in the sitting position over fifteen minutes. NCT was performed before the GAT to avoid the known mild reduction of IOP by anterior chamber compression with GAT. RESULTS The study included 200 eyes of 100 patients. Mean age of the patients was 58.14 ± 11.7 years (range 35- 81 years). The study population consisted of 58 males and 42 females. The mean ± SD intraocular pressure measurements were 23.39 ± 4.6 mmHg and 22.41 ± 5.9 mmHg for NCT and GAT, respectively. The difference between the NCT and GAT IOP was 0.98 ± 4.7 mm Hg. Mean CCT of the study group was 545.74 ± 38.23 microns. The IOP measured with both GAT and NCT showed no significant change with increasing CCT. The difference between the means increases with increasing CCT upto 600 microns. At lower IOPs ≤ 20 mm Hg, GAT measures are higher than NCT and this relationship is reversed at high IOPs. CONCLUSION Intraocular pressure measurement by NCT was consistently higher than GAT. There was a tendency for NCT to underestimate IOP at lower ranges and overestimates IOP at higher ranges. By applying appropriate correction factor for CCT, Noncontact tonometry could be used as a good screening tool for glaucoma evaluation.
Subjects
Nursing & HealthcareAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
More from this journal
The newest in Journal of Evidence-Based Medicine and Healthcare.
Article · 28 Jul 2025
Association between Admission Blood Pressure, Stroke Severity and Early Outcome in Thrombolysed Ischemic Stroke Patients: A Single Centre Experience from Northeast India
Article · 28 Mar 2025
Isolated Paralysis of Extensor Indicis and EDC Tendon of Index Finger Following Thompsonandrsquo;s Approach to Proximal Radius-Case Report
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Evidence-Based Medicine and Healthcare
- SubjectNursing & Healthcare
- BylineArticles whose byline prints “Radhakrishnan B”
- BylineArticles whose byline prints “Hemapriya S”
- BylineArticles whose byline prints “Nazeem Farzana Ghouse”
- BylineArticles whose byline prints “Aparna Rajagopalan”