Scholars Central

ArticlePublished 2017

Patient Outcomes Following Posterior Lumbar Interbody Fusion for Adjacent Segment Disease Using VariLiftÃ?â??Ã?® as a Standalone Expandable Interbody Device

Authors: Bryan J Wohlfeld, Diana Cardenas Del Monaco

Journal of Spine

Volume 6 · Issue 4 · Pages 1–6

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Background: Adjacent Segment Disease (ASD) is a notable complication following lumbar fusion surgery. Clinicians use various surgical techniques to correct the progression of spine deterioration and reduce the risk of continued ASD. The aim of this retrospective case series is to describe patient outcomes following posterior lumbar interbody fusion (PLIF) using the VariLift® standalone interbody device (without supplemental fixation) for the treatment of ASD. Methods: Nine consecutive patients who underwent a single-level PLIF for the treatment of ASD were reviewed. Outcome measures included patient demographics, comorbidities, surgical complications, time to fusion, Visual Analog Scales for Pain (VAS), and overall patient reported recovery of symptoms. Nine patients (8 males, 1 female) with a mean age of 62.3 (42 to 72) years underwent a single-level procedure. The standalone VariLift interbody fusion system was used in all 9 sequential patients, regardless of the type of fusion/fixation instrumentation previously used. Surgical technique consisted of discectomy and generous bilateral laminotomies with medial facetectomies preserving midline ligamentous structures. Results: Radiographic ASD was confirmed in all cases. Each patient had a history of a lumbar fusion. Preoperatively, 89% of patients reported 9-10 VAS back pain levels. All patients experienced symptomatic improvement. By 12 months postoperatively, average VAS back pain score was 2, a significant improvement from baseline (p<0.05). Solid interbody fusion without implant failure was observed in all cases with averaged time to fusion at 346 days (min=181 days). Conclusion/level of evidence: Posterior lumbar interbody fusion using the VariLift device to treat symptomatic ASD offers significant clinical success and solid fusion rates without the need for supplemental fixation or extension of previous supplemental fixation. Level of evidence IV. Clinical relevance: This stand-alone fusion device produced high fusion rates and symptomatic improvement in a sample of patients with severe back pain and ASD.

Subjects

Orthopaedics

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Journal of Spine.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Spine
  • SubjectOrthopaedics
  • BylineArticles whose byline prints “Bryan J Wohlfeld”
  • BylineArticles whose byline prints “Diana Cardenas Del Monaco”