Article · 7 Oct 2025
Research articlePublished 4 Oct 2016
COMPARISON OF PREOPERATIVE NONINVASIVE AND INTRAOPERATIVE MEASUREMENTS OF AORTIC ANNULUS
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
BACKGROUND Precise preoperative assessment of aortic annulus diameter is essential for sizing of aortic valve especially in patients planned for transcatheter aortic valve replacement. Computed Tomographic (CT) and echocardiographic measurements of the aortic annulus vary because of elliptical shape of aortic annulus. This study was undertaken to compare the measurement of aortic annulus intraoperatively with preoperative noninvasive methods in patients undergoing aortic valve replacement. MATERIALS AND METHODS Aortic annulus diameter was measured with cardiac CT and Transesophageal Echocardiography (TEE) prior to open aortic valve replacement in 30 patients with aortic valve stenosis. In CT, aortic annulus dimensions were measured in coronal plane, sagittal oblique plane and by planimetry. Both 2-dimensional and 3-dimensional TEE were used. These were compared with intraoperative measurements done by valve sizers and Hegar dilators. Pearson analysis was applied to test for degree of correlation. RESULTS CT in coronal and sagittal oblique plane tends to overestimate the diameter of aortic annulus when compared with intraoperative measurements (coefficient of relation, r = 0.798 and 0.749, respectively). CT measurements in single oblique plane showed a weaker correlation with intraoperative measurements than 3D TEE and 2D TEE (r = 0.917 and 0.898, respectively). However, CT measurements by planimetry method were most correlating with the intraoperative measurements (r = 0.951). CONCLUSION Noninvasive investigations with 3-dimensional views (CT-based measurement employing calculated average diameter assessment by planimetry and 3-dimensional TEE) showed better correlation with intraoperative measurement of aortic annulus. CT-based aortic annulus measurement by planimetry seems to provide adequate dimensions most similar to operative measurements.
Keywords
Subjects
Nursing & HealthcareAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
More from this journal
The newest in Journal of Evidence-Based Medicine and Healthcare.
Article · 28 Jul 2025
Association between Admission Blood Pressure, Stroke Severity and Early Outcome in Thrombolysed Ischemic Stroke Patients: A Single Centre Experience from Northeast India
Article · 28 Mar 2025
Isolated Paralysis of Extensor Indicis and EDC Tendon of Index Finger Following Thompsonandrsquo;s Approach to Proximal Radius-Case Report
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Evidence-Based Medicine and Healthcare
- SubjectNursing & Healthcare
- BylineArticles whose byline prints “Manish Hinduja”
- BylineArticles whose byline prints “Vivek Wadhawa”
- BylineArticles whose byline prints “Sandip Singh Rana”
- BylineArticles whose byline prints “Harkant Singh”
- BylineArticles whose byline prints “Parmindrer Singh”
- BylineArticles whose byline prints “Manphool Singhal”
- BylineArticles whose byline prints “Chirag Doshi”
- BylineArticles whose byline prints “Amber Malhotra”