Scholars Central

Research articlePublished 2013

Investigation of Correction Method of Recovery Effect and Motion Blur for SUV Quantification in FDG PET/CT in Patients with Early Lung Cancer

Authors: Noriyuki Kadoya, Yukio Fujita, Kengo Ito, Suguru Dobashi, Ken Takeda, Kazuma Kishi, Takaya Yamamoto, Rei Umezawa, Toshiyuki Sugawara, Tomohiro Kaneta, Haruo Matsushita, Keiichi Jingu

Nuclear Medicine & Radiation Therapy

Volume 4 · Issue 4 · Pages 1–8

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Objective: We investigated the effects of partial volume and respiratory motion using a National Electrical Manufacturers Association (NEMA) phantom and proposed a simple method for correction of maximum standardized uptake value (SUVmax) for respiratory motion in early lung cancer. Methods: The maximum recovery coefficient (RC) in static mode were measured using the NEMA phantom and a dynamic moving platform. The phantom on the platform was either at rest or moving sinusoidally along the longitudinal axis of the scanner to simulate respiratory motion. We also calculated estimated RC using our approximation. Results: RC of the sphere of 28mm in diameter decreased from 0.96 to 0.80 and 0.41 with 20 and 50 mm of motion amplitude, respectively. For the sphere of 10 mm in diameter, RC was decreased from 0.40 to 0.18 and 0.08 with 20 and 50 mm of motion amplitude, respectively. Our results showed that RC decreased with increase in motion amplitude. Average percentage differences between measurement and estimation in the sphere of 37, 28, 22, 17, 13 and 10 mm were -1.8 ± 3.7, -3.1 ± 11.3, -2.8 ± 10.5, -8.1 ± 6.6, -7.0 ± 12.3 and -1.8 ± 12.2 %, respectively. This result showed that our simple correction method could estimate SUVmax with moderate accuracy. Conclusions: Our results clearly demonstrated that RC decreases with increase in motion amplitude, as expected. Our simple correction with moderate accuracy method could not precisely estimate RC. However, the estimated values agreed with the measurements. Thus, our methods could be used in clinical practice to calculate the approximate SUVmax for lung cancer patients undergoing radiotherapy showing the malignancy grading for early lung cancer.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Nuclear Medicine & Radiation Therapy.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalNuclear Medicine & Radiation Therapy
  • SubjectRadiology & Imaging
  • SubjectEnergy & Power
  • BylineArticles whose byline prints “Noriyuki Kadoya”
  • BylineArticles whose byline prints “Yukio Fujita”
  • BylineArticles whose byline prints “Kengo Ito”
  • BylineArticles whose byline prints “Suguru Dobashi”
  • BylineArticles whose byline prints “Ken Takeda”
  • BylineArticles whose byline prints “Kazuma Kishi”
  • BylineArticles whose byline prints “Takaya Yamamoto”
  • BylineArticles whose byline prints “Rei Umezawa”