Scholars Central

ArticlePublished 19 Dec 2016

BEDSIDE TRANSORBITAL SONOGRAPHIC EVALUATION OF OPTIC NERVE SHEATH DIAMETER IN HEALTHY SOUTH INDIAN POPULATION

Authors: Uday Kumar Jaihind Khasage, Vijaya Kumar, Narendra Sharanappa Shamanur, Bakkesh Budhihal Prasad, Bharath Kempanna, Ganesha Billahalli Siddappa, Ashray Vasanthapuram, Sachin Nayak Sujir

Journal of Evidence-Based Medicine and Healthcare

Volume 3 · Issue 12 · Pages 1–4

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

BACKGROUND Optic nerve sheath ultrasonography provides a very promising bedside tool for the detection of raised ICP. Since the optic nerve is a part of the central nervous system, it is surrounded by Cerebrospinal Fluid (CSF).1 Measurement of Optic Nerve Sheath Diameter (ONSD) by ultrasound is increasingly used as a marker to detect raised Intracranial Pressure (ICP). ONSD varies with age and there is no clear consensus between studies for an upper limit of normal. Knowledge of normal ONSD in a healthy population is essential to interpret this measurement.2-4 The aim of the study is to measure the optic nerve sheath diameter in normal individuals using bedside ultrasonography in both eyes. To categorise the variations in optic nerve sheath diameter according to individual eye, age, sex and to evaluate any of the parameters, which will have influence on the variations. MATERIALS AND METHODS This was a prospective observational study on normal population with sample size of 500. Data was obtained from measuring ONSD from normal individuals with no symptoms or signs of raised intracranial tension (healthy volunteers). The measurements was taken by using a 7.5 MHz linear ultrasound probe and measurements were taken 3 mm posterior to the optic disc. Measurements each subject had the ONSD from both eyes measured twice and an average taken for each eye. The results obtained were correlated for variations across the individual eyes, age groups and sex of the individual by using appropriate statistical analysis. RESULTS Total of 500 subjects were enrolled in our study. Of that, 280 (56%) were males and 220 (44%) were females. The mean ONSD obtained separately for males, females according to age distribution for each eye. There was not much deviation from the standard value for each of different eyes or age groups. Mean ONSD for males 4.5-5.2 (4.8±0.3 mm) and females 4.7-5.1 (4.9±0.2 mm). CONCLUSION Standard reference value for normal optic nerve sheath diameter by using ultrasound in southern part of India can be taken between 4.5 to 5.2 mm. It has been observed in our study that the standard value doesn’t change much with the age or gender.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Journal of Evidence-Based Medicine and Healthcare.

All its articles

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Evidence-Based Medicine and Healthcare
  • SubjectNursing & Healthcare
  • BylineArticles whose byline prints “Uday Kumar Jaihind Khasage”
  • BylineArticles whose byline prints “Vijaya Kumar”
  • BylineArticles whose byline prints “Narendra Sharanappa Shamanur”
  • BylineArticles whose byline prints “Bakkesh Budhihal Prasad”
  • BylineArticles whose byline prints “Bharath Kempanna”
  • BylineArticles whose byline prints “Ganesha Billahalli Siddappa”
  • BylineArticles whose byline prints “Ashray Vasanthapuram”
  • BylineArticles whose byline prints “Sachin Nayak Sujir”