Scholars Central

Conference abstractPublished 20 Jun 2022

Evaluation of two CAD software on the adaptation of digitally constructed maxillary complete denture

Authors: Fardos N. Rizk

The British University in Egypt (BUE), Egypt

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Aim: This study was conducted to evaluate the adaptation of maxillary complete denture designed by two different open computer-aided design software programs (3Shape and Exocad) using Geomagic surface matching software. Settings and Design: This was a nonrandomized crossover clinical trial. Materials and Methods: Twenty completely edentulous patients were selected in this study. Forty complete dentures were designed using two different software programs: twenty dentures were designed by 3Shape software, and the other twenty dentures were designed by Exocad software. Maxillary dentures were evaluated regarding their adaptation by measuring the deviations that occurred between the fitting surface of the three-dimensional printed dentures, and the scanned master casts using Geomagic surface matching software. Statistical Analysis Used: An unpaired t-test was used for statistical analysis. Results: According to the positive average deviation value that represented pressure areas, 3Shape-designed maxillary dentures showed significantly lower mean deviation values (0.041115 ± 0.018165 mm) than Exocadâ??designed maxillary dentures (0.500665 ± 0.032619 mm). Regarding the negative average deviation values that represented the gap areas, Exocad-designed maxillary dentures showed significantly lower mean deviation values (0.161555 ± 0.007842 mm) than 3Shapeâ??designed maxillary dentures(0.231350 ± 0.009146 mm). The results of the total average deviation values showed significantly lower mean deviation values(0.096950 ± 0.008868 mm) of 3Shapeâ??designed maxillary dentures than Exocad-designed maxillary dentures (0.250755 ± 0.021154 mm). Conclusion: 3Shape and Exocad software programs produced acceptable maxillary dentures regarding denture adaptation. However, maxillary dentures designed by 3 Shape software showed better adaptation than maxillary dentures designed by Exocad software. Keywords: 3Shape software, computerâ??aided design, denture adaptation, digital complete dentures, Exocad software, Geomagic software.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalOral Health Case Reports
  • SubjectDentistry & Oral Health
  • BylineArticles whose byline prints “Fardos N. Rizk”