Although endoleaks have been well described after endovascular abdominal aortic aneurysm (AAA) repair, their occurrence after open repair is much less common. This case report describes a patient who had a leak at the proximal anastomotic site of the graft after open AAA repair. The patient was a 78 year old male patient who presented to our facility with bright red blood from the rectum at approximately 3 months after an open AAA repair at an outside facility. On computed tomographic angiography, a leak was detected at the proximal anastomotic site and resembled a type I endoleak that may occur after endovascular repair. The patient was treated through endovascular technique with the placement of two proximal extension cuffs. The endoleak was not observed on follow-up imaging, and the patient has been asymptomatic since treatment. Endoleaks after open AAA repair are rare, but they can be treated through an endovascular approach, with proximal extension cuff placement to seal the leak.

Subjects

Cardiology

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Journal of Vascular and Endovascular Therapy.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Vascular and Endovascular Therapy
  • SubjectCardiology
  • BylineArticles whose byline prints “Albert G Hakaim”
  • BylineArticles whose byline prints “Charles G Stoneburner”
  • BylineArticles whose byline prints “Gregory Frey”