Scholars Central

Research articlePublished 24 Jan 2017

Study of Breath Acetone in a Rat Mode of 126 Rats with Type 1 Diabetes

Authors: Zhennan Wang, Meixiu Sun, Xiaomeng Zhao, Chenyu Jiang, Yingxin Li, Chuji Wang

Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin, China; Department of Physics and Astronomy, Mississippi State University, MS, USA

Journal of Analytical & Bioanalytical Techniques

Volume 8 · Issue 1 · Pages 1–5

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

We investigate correlations of breath acetone with blood glucose (BG) and blood beta-hydroxybutyrate (BHB) in a rat model of 126 streptozotocin-induced Type 1 diabetic (T1D) and 32 healthy rats, and evaluate the role of breath acetone analysis as a non-invasive alternative in diabetes screening and management. We conducted breath acetone analysis using a T1D rat model under various conditions, including fasting and insulin-treated. Breath acetone concentrations were measured using a cavity ringdown breath acetone analyzer, LaserBreath-001. The results showed that the breath acetone, BG, and BHB in the T1D rat group were significantly different from those in the healthy group (P<0.05). Significant positive relationships between breath acetone and blood BHB existed in both T1D and healthy groups, as well as in a group of T1D rats under fasting condition and insulin treatment. When the BG concentrations were grouped as follows: 16.5-24.4, 24.5-27.7, and 27.8-41.7 mmol/L, a moderate negative correlation between breath acetone and BG was observed in the T1D group. Furthermore, the accuracy of diabetes screening using breath acetone was analyzed using the receiver operating characteristic (ROC) analysis method and results showed that the accuracy is low when the area under ROC curve (AUC) is <0.6425.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Journal of Analytical & Bioanalytical Techniques.

All its articles

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Analytical & Bioanalytical Techniques
  • SubjectBiochemistry & Biotechnology
  • SubjectChemistry
  • BylineArticles whose byline prints “Zhennan Wang”
  • BylineArticles whose byline prints “Meixiu Sun”
  • BylineArticles whose byline prints “Xiaomeng Zhao”
  • BylineArticles whose byline prints “Chenyu Jiang”
  • BylineArticles whose byline prints “Yingxin Li”
  • BylineArticles whose byline prints “Chuji Wang”