outpatient clinic. Patients were divided into Group (I): 12 patients had received two titanium implant with bar retained overdentures and Group (II): 12 patients had received two titanium implant with
potential replacement of Ti-Ni alloys in biomedical applications. The β type titanium alloys attracted to attention for biomedical because of their low stiffness, good corrosion resistance, biocompatible, and…
broke the right elbow and right leg, requiring surgery with surgical implant of titanium rod in both limbs. Two months after surgery the patient presented a very severe depression, that ... antidepressants. The second…
response to surfaces treated with bioactive polymers: case of poly (sodium styrene sulfonate) grafted titanium surfaces. Journal of Material Sciences: Material in Medicine
polyester (PES), woven fabric) with a hybrid photocatalytic material based on Cellulose Nanocrystals (CNC)/titanium dioxide (TiO2) in order to photodegrade VOCs under visible light. This study presents the first
success of this therapy. Material and methods: Fifty-four patients underwent implantation therapy by titanium implants from BTLock company (Italy). Before dental implantation therapy started, saliva samples from…
lattice band gap. In this work, we made powder and Nano-structured film of titanium dioxide doped with various molar ratios of Mg by the sol-gel process. The effect
without disruption of the ingrown port. The PVAS port is comprised of a percutaneous titanium conduit with a subcutaneous titanium mesh ingrowth cuff and a disengageable silicone brake. Feedback from
difficulties of effectively designing and implementing a CSC. Three metal oxide/silicon heterojunctions - titanium dioxide/silicon (TiO2/Si), zinc oxide/silicon (ZnO/Si), and tin dioxide/silicon (SnO2/Si) - initially…
Khan S U M (2016) Photocatalytic removal of polychlorinated biphenyls (PCBs) using carbon- modified titanium oxide nanoparticles. Applied Surface Science 365:108–113. 3. Kavil Y N, Shaban
tetragonal structure. The UV-Visible Spectroscopy Analysis was found that incorporation of Cu2+ into titanium affects the band gap of TiO2 and extending his activity towards visible sunlight region. Scanning
subgroups according to scaling tip material; stainless steel tip (S), plastic tip (P) and titanium tip (T). The surface texture was analyzed quantitatively and qualitatively with a profilometer ... scaled surfaces and…
residual cyst and 1 patient developed recurrence after initial healing response. Conclusion: Titanium intramedullary nailing is a safe and efficient procedure for unicameral bone cyst as it provides immediate mechanical
increasing demand for orthopedic implants owing to the increasing numbers of aging population. Titanium alloy (Ti6Al4V) is a common material used for orthopedic implants owing to its advantageous properties…
that pure Ni is a toxic element and causes Ni-hypersensitivity. The β-type titanium alloys attracted to attention for bio-medical because of their low stiffness, good corrosion resistance ... nanoindentation test. The…
present study, a microstructure-based finite element model for a two phase titanium aluminide alumina cermet is proposed based on a modified Gurson model. A face-centered cubic unit cell
like bone grafts or platelet-rich in fibrin. Beyond, it permits to personalize the titanium mesh through the prototyping printed and others applications that become the complex procedures simpler. Although
materials were used in formulating quasisolid electrolyte compositions and incorporated into flexible dye-sensitized titanium oxide solar cells (DSSC). It was observed that the solar conversion efficiency of quasi-solid
were used in formulating quasi-solid electrolyte compositions and incorporated into flexible dye-sensitized titanium oxide solar cells (DSSC). It was observed that the solar conversion efficiency of quasi-solid
periodontal therapy should be noted. Mechanical debridement can be done with carbon, plastic or titanium currets, ultrasonic scaling or powder air abrasion. Full Mouth Dental Implants in Turkey: Affordable Package
literature on the adaptation of structures of prostheses on prefabricated implants or melted in titanium, before and after laser welding. It was used as methodology a scan was carried
isothermal forging of titanium aluminides takes place between 1100°C and 1250°C with very low strain rates. This requires materials for the forming tools which have high stability ... resistance. At present, forging…
samples is discussed. The miniature samples were used for determination of mechanical properties for titanium alloy deposited by additive manufacturing. The tensile tests on the standard and the miniature samples…
advantages include using biocompatible elements and lower elastic modulus. A new developed beta titanium alloy (Ti-Nb-Ta-Zr-O) was prepared by sequential plasma arc melting but was prepared
IPEN (Institute of Energy and Nuclear Research). Lead, cadmium, chromium, arsenic, mercury, aluminum, manganese, titanium, and phthalates are heavy metals often used by the cosmetic industry to improve the structure
For authors and organisers
Publish, present and keep up with your field