A New Control Strategy for Harmonic Elimination Using shunt Active Filter
Load compensators are used for reactive power compensation as well as harmonic
Articles, journals and conferences in one search. An exact title, DOI or ISSN is listed first.
In the search box: "exact phrase" · -leave out · OR · prefix* · title: author: journal:
Load compensators are used for reactive power compensation as well as harmonic
At the PCC and source side current and voltage harmonics is compensated
In DC hybrid system voltage fluctuations are induced at the Point of
The electric drives play a vital role on the productivity to any
experiments were performed: the proportional controller (P) and the other for the Proportional-Integral controller (PI). The response variable is lambda , which is the parameter that is varied ... this research are…
source voltage and critical or sensitive load. This paper describes DVR using Proportional Integral (PI) control technique. The simulations are performed using Matlab/Simulink’s SimPowersystem Toolbox
sliding mode controller is compared with Proportional Integral Derivative (PID) controller and Proportional Integral (PI) controller. Simulation results shows that the sliding mode control scheme provides good voltage…
Hysteresis current controller using single current sensor is used for current control and Proportional Integral (PI) controller is used for speed control. The performance of the drive system was verified
converter to obtain the high output voltageand it is controlled by the Proportional Integral (PI) controller. Soft switching technique is also implemented to improve the performance of converter. The Zero
control strategy is based on the feed forward current control method using conventional Proportional Integral (PI) controller in the synchronous rotating reference frame
damping electromechanical oscillations in comparison with the conventional fuzzy logic controller and conventional proportional-integral (PI) controller
this paper, Proportional Integral (PI) Controllers are designed for unstable Multi Input Multi Output system with delay based on the equivalent transfer function (ETF) model. Decoupling method is proposed
voltage is caused due to switching loss. The control strategy used is using PI (Proportional Integral) controller and hysteresis control. This control scheme has the advantage of good stability
range of load variation. Also this efficient converter is controlled using the conventional proportional-integral (PI) controller and fuzzy logic controller (FLC). The performance parameters are compared and found that
Simulink/MATLAB. The PSO tuned controller showed better performance with respect to conventional Proportional Integral (PI) controller and non-tuned FLC controller
proposed system is done using MATLAB version 2013a and the simulation results of proportional-integral (PI) controller and fuzzy logic controller(FLC) method is compared
inverter that mitigates the lower order harmonics is presented in this project. A proportional-integral (PI) controller are implemented in order to overcome the lower order harmonic distortions. Low total
traditional voltage and current source inverters cannot provide such feature. Normally, the proportional integral (PI) control is commonly used in the stationary reference frame for current controlled inverters. However…
This paper presents the current control of three phase induction motor using Fuzzy logic. A thyristorized AC voltage Inverter is utilized as the starting ... equipment while the motor current regulation is carried out…
simple circuit controller of Brushless Direct Current (BLDC) motor for electric vehicle implementation. This control based on the function relationship between the Hall sensor logics and currents that should ... added…
design the POD controller for SSSC. This research is carried on a modified Heffron-Phillips model of a single machine infinite bus (SMIB) system integrated with SSSC. In the following ... HFLDC in damping…
brushless DC (BLDC) motor drive system that incorporates a motor controller with proportional integral (PI) speed control loop using MATLAB/Simulink is used to build the dynamic model and simulate
used to produce conductance command for SAPF. The voltage loop is operated by proportional integral (PI) controller. This control method provides reduced THD and the improvement of fundamental component
induction motor drive that minimizes total losses and optimizes efficiency through optimal control using proportional plus integral (PI) and fuzzy logic controller. Loss minimization is obtained by proper designing
The conventional full-wave diode bridge rectifier with an output capacitor filter
For authors and organisers
Find the right journal for your paper and submit your manuscript.