Scholars Central

Conference abstractPublished 23 Oct 2017

Electro-membrane extraction combined with capillary electrophoresis for the determination of metoclopramide and ondansetron in urine samples

Authors: Ehsan Sadeghi, Ali Reza Fakhari

Shahid Beheshti University, Iran

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Electromembrane extraction (EME) is a sample preparation technique in pharmaceutical, chemical, clinical and environmental analysis. This technique uses electromigration across artificial liquid membranes for selective extraction of analytes and sample enrichment from complex matrices. This method has many advantages such as simplicity, rapid, low-cost, low LOD, high preconcentration factor and high recovery. In the present work, simultaneous preconcentration and determination of two basic drugs namely metoclopramide (MCP) and ondansetron (OSN) were studied using EME as a suitable extraction method, followed with capillary electrophoresis (CE) using ultraviolet (UV) detection as separation technique. The drugs were extracted from 4 ml sample solutions, through a supported liquid membrane (SLM) consisting 2-nitrophenyloctylether (NPOE) impregnated in the walls of a polypropylene hollow fiber, and into a 20 Ã?¼L acidic aqueous acceptor solution resent inside the lumen of the hollow fiber with a potential difference applied over the SLM. The variables of interest, such as chemical composition of the organic liquid membrane, stirring speed, extraction time and voltage, pH of donor and acceptor phases and salt effect in the EME process were investigated and optimized. Under optimal conditions NPOE as SLM, stirring rate of 1000 rpm, 200 V potential differences, 20 min as the extraction time, acceptor phase HCl (pH 1.0) and donor phase HCl (pH 1.5). After the microextraction process, the extracts were analyzed by CE with optimum conditions phosphate running buffer (pH 2.0), applied voltage of 20 kV and 25Ã?°C. Under the optimum conditions, limits of detection (LOD) and quantification (LOQ) for MCP and OSN were 2.31-2.68 and 7.72-8.91 ng mL-1 respectively. Preconcentration factor and RSD for five replicates of each drug were calculated to be 200 and 4.06-3.93 respectively. Finally, the applicability of this method was studied by the extraction and determination of these drugs in urine samples with recovery percentages of 87âÂ?Â?92%.

Subjects

Chemistry

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Journal of Chromatography & Separation Techniques.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Chromatography & Separation Techniques
  • SubjectChemistry
  • BylineArticles whose byline prints “Ehsan Sadeghi”
  • BylineArticles whose byline prints “Ali Reza Fakhari”