Research article · 15 Sep 2026
Conference abstractPublished 19 Jun 2017
Top-down analysis of a FMN-binding membrane protein (FMP) using a multiplexing FTMS data workflow combined with an in-house web-free access ChemInfo.org tool
ISIC-GE, Lausanne, Switzerland; ISIC-GE, Sion, Switzerland; Ã?Â?cole Polytechnique FÃ?©dÃ?©rale de Lausann, Switzerland; Spectroswiss SÃ? rl, Switzerland
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Top-down protein structural analysis, increasingly used to assess drug-protein binding sites, benefits from high-resolution and high mass accuracy offered by Fourier transform MS/MS. To improve localization of post-translational modifications and FMNbinding sites on a 19 kDa membrane protein (FMP), we implemented the following workflow on Orbitrap FTMS platforms. First, to increase sensitivity and dynamic range, we acquire a number (up to 10) of consecutive LC-MS/MS experiments (using HCD) from the same sample. Second, we record in parallel both standard mass spectra in raw format using original on-board data processing system (Thermo Scientific) and time-domain signals (transients) using an external high-performance data acquisition system (FTMS Booster X1). The transients are summed across all LC-MS/MS runs, processed with absorption mode FT, the mass spectra are recalibrated and baseline corrected to generate an accurate peak list (using Peak-by-Peak software). Finally, we apply the in-house developed free-access ChemInfo.org algorithms for predicting and matching the experimental tandem spectra to theoretical fragment ions, in particular internal fragment ions which proved to be crucial for precise localization of FMN binding sites. This versatile tool allows fast and automatic matching of thousands of peaks from complex mass spectra. The localization of the FMN-binding site on the FMP protein was restricted to a string of four residues, among which the threonine was presumably the binding site. The results in terms of number and confidence of fragment ion assigned, similarity scores and localization of FMN binding sites were favorably compared to the classical top-down analysis using a single LC-MS/MS run.
Subjects
ChemistryAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
More from this journal
The newest in Journal of Chromatography & Separation Techniques.
Commentary · 7 Jul 2025
Development and validation of a quantification method of urinary free cortisol in 24 hours urine by mass detection.
Commentary · 28 Jun 2025
Advancements and Methodologies of Column Chromatography
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Chromatography & Separation Techniques
- SubjectChemistry
- BylineArticles whose byline prints “Laure Menin”
- BylineArticles whose byline prints “Natalia Gasilova”
- BylineArticles whose byline prints “Daniel Ortiz”
- BylineArticles whose byline prints “Luc Patiny”
- BylineArticles whose byline prints “Julien Maillard”
- BylineArticles whose byline prints “Konstantin O Nagornov”
- BylineArticles whose byline prints “Yury Tsybin”