Scholars Central

Research articlePublished 29 Nov 2021

Validated HPLC method for Identification and Quantification of 4-Hydroxy Benzoic Acid in Levetiracetam Oral Solution Drug Product Formulation

Authors: MSN Reddy, Gopalakrishnan Venkatasami, Venkata R Kotta, Muruganantham Ramamoorthy, Shreya Patel

Journal of Chromatography & Separation Techniques

Volume 12 · Issue 11 · Pages 1–6

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

A simple, selective, sensitive, accurate and precise RP-HPLC method was developed for the identification and quantification of 4-hydroxy benzoic acid which is the main degradation product from parabens in Levetiracetam Oral solution. The separation was performed on a C18-column using a mobile phase 0.1% Phosphoric acid buffer as mobile phase A and 100% Acetonitrile as a mobile phase-B in a gradient elution. The detection was performed at a fixed wavelength (λ=230 nm), with a flow rate of 1.0 ml/min. The retention time of 4-Hydroxy Benzoic acid and Levetiracetam were found to be 11.78 min and 9.03 minutes, respectively. After developing the method, it was assured for the intended use by validation of the analytical parameters like linearity, accuracy, precision, limit of detection, limit of quantitation and robustness. The results of all the parameters of the method were found to be within the acceptance criteria as per the International Council for Harmonization (ICH) guidelines. The detector response was linear in concentrations ranging from 0.5033 μg/mL (0.05%)-4.0264 μg/mL (0.4%) of 4-Hydroxy benzoic acid. The Limit of Detection (LOD) and Limit of Quantification (LOQ) of p-Hydroxy Benzoic acid were found to be 0.1007 μg/mL and 0.5033 μg/mL. The intra and inter day variations were found to be less than 2%. The analytical recoveries of 4-hydroxy benzoic acid are ranges from 94.6% to 107.2%. The proposed method was used to monitor the degradation of the parabens in Levetiracetam Oral solution drug product USP100 mg/5 mL formulation.

Subjects

Chemistry

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Journal of Chromatography & Separation Techniques.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Chromatography & Separation Techniques
  • SubjectChemistry
  • BylineArticles whose byline prints “MSN Reddy”
  • BylineArticles whose byline prints “Gopalakrishnan Venkatasami”
  • BylineArticles whose byline prints “Venkata R Kotta”
  • BylineArticles whose byline prints “Muruganantham Ramamoorthy”
  • BylineArticles whose byline prints “Shreya Patel”